Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
Am Heart J ; 188: 167-174, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28577672

RESUMO

The Carillon Mitral Contour System has been studied in 3 nonrandomized trials in patients with symptomatic congestive heart failure and functional mitral regurgitation. The REDUCE FMR study is a uniquely designed, double-blind trial evaluating the impact of the Carillon device on reducing regurgitant volume, as well as assessing the safety and clinical efficacy of this device. Carillon is a coronary sinus-based indirect annuloplasty device. Eligible patients undergo an invasive venogram to assess coronary sinus vein suitability for the Carillon device. If the venous dimensions are suitable, they are randomized on a 3:1 basis to receive a device or not. Patients and assessors are blinded to the treatment assignment. The primary end point is the difference in regurgitant volume at 1 year between the implanted and nonimplanted groups. Other comparisons include clinical parameters such as heart failure hospitalizations, 6-minute walk test, Kansas City Cardiomyopathy Questionnaire (KCCQ), and other echocardiographic parameters. An exercise echo substudy will also be included.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/complicações , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Método Duplo-Cego , Ecocardiografia , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
3.
BMC Cardiovasc Disord ; 15: 43, 2015 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-25971307

RESUMO

BACKGROUND: To determine the cost-effectiveness of the percutaneous mitral valve repair (PMVR) using Carillon® Mitral Contour System® (Cardiac Dimensions Inc., Kirkland, WA, USA) in patients with congestive heart failure accompanied by moderate to severe functional mitral regurgitation (FMR) compared to the prolongation of optimal medical treatment (OMT). METHODS: Cost-utility analysis using a combination of a decision tree and Markov process was performed. The clinical effectiveness was determined based on the results of the Transcatheter Implantation of Carillon Mitral Annuloplasty Device (TITAN) trial. The mean age of the target population was 62 years, 77% of the patients were males, 64% of the patients had severe FMR and all patients had New York Heart Association functional class III. The epidemiological, cost and utility data were derived from the literature. The analysis was performed from the German statutory health insurance perspective over 10-year time horizon. RESULTS: Over 10 years, the total cost was €36,785 in the PMVR arm and €18,944 in the OMT arm. However, PMVR provided additional benefits to patients with an 1.15 incremental quality-adjusted life years (QALY) and an 1.41 incremental life years. The percutaneous procedure was cost-effective in comparison to OMT with an incremental cost-effectiveness ratio of €15,533/QALY. Results were robust in the deterministic sensitivity analysis. In the probabilistic sensitivity analysis with a willingness-to-pay threshold of €35,000/QALY, PMVR had a 84 % probability of being cost-effective. CONCLUSIONS: Percutaneous mitral valve repair may be cost-effective in inoperable patients with FMR due to heart failure.


Assuntos
Implante de Prótese de Valva Cardíaca/economia , Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/economia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Análise Custo-Benefício , Árvores de Decisões , Feminino , Alemanha , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Anos de Vida Ajustados por Qualidade de Vida , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...